Cazadero, CA

      Site ID:     czc
      Latitude:     38.610700 N
      Longitude:     -123.215200 W
      Elevation:     478 meters
      Active:     Y
      Site Table:     Site Table
      Data:     Realtime Display

Instrument Name     Project Name     Install Date     Data Types
Tipping Bucket TE525     Hydrometeorology Testbed - West     2005-11-16          view
Pressure - PTB101B     Hydrometeorology Testbed - West     2005-11-16          view
Temp/RH HMP45C     Hydrometeorology Testbed - West     2005-11-16          view
Wind Speed and Direction 5103     Hydrometeorology Testbed - West     2005-11-16          view
Solar Radiation CM3     Hydrometeorology Testbed - West     2005-11-16          view
Net Radiation REBS Q7.1     Hydrometeorology Testbed - West     2005-11-16          view
Soil Moisture 10cm     Hydrometeorology Testbed - West     2005-11-16          view
Soil Moisture 15cm     Hydrometeorology Testbed - West     2005-11-16          view
Soil Temperature 10cm     Hydrometeorology Testbed - West     2005-11-16          view
Soil Temperature 15cm     Hydrometeorology Testbed - West     2005-11-16          view
Soil Moisture 5cm     Hydrometeorology Testbed - West     2012-05-23          view
Soil Moisture 20cm     Hydrometeorology Testbed - West     2012-05-23          view
Soil Moisture 50cm     Hydrometeorology Testbed - West     2012-05-23          view
Soil Moisture 100cm     Hydrometeorology Testbed - West     2012-05-23          view
Soil Temperature 5cm     Hydrometeorology Testbed - West     2012-05-23          view
Soil Temperature 20cm     Hydrometeorology Testbed - West     2012-05-23          view
Soil Temperature 50cm     Hydrometeorology Testbed - West     2012-05-23          view
Soil Temperature 100cm     Hydrometeorology Testbed - West     2012-05-23          view
Soil Heat Flux - HFT-3.1     Hydrometeorology Testbed - West     2012-05-23          view
3 GHz Precipitation Profiler Analog     Hydrometeorology Testbed - West     2015-10-07          view
Disdrometer Joss Impact RD-80     Hydrometeorology Testbed - West     2015-10-08          view
Datalogger CR3000     Hydrometeorology Testbed - West     2012-05-23          view

Instrument Name     Project Name     Install Date     Removal Date     Data Types
Datalogger CR10X     Hydrometeorology Testbed - West     2005-11-16     2005-11-16          view
3 GHz Precipitation Profiler Analog     Hydrometeorology Testbed - West     2003-12-19     2011-05-03          view
3 GHz Precipitation Profiler Analog     Hydrometeorology Testbed - West     2011-11-16     2012-05-22          view
Disdrometer Joss Impact RD-80     Hydrometeorology Testbed - West     2011-11-18     2012-05-22          view
GasAnalyzer - LI-7500     Hydrometeorology Testbed - West     2012-05-23     2021-10-06          view
Sonic Anemometer - SATI-3K     Hydrometeorology Testbed - West     2012-05-23     2021-10-06          view
Disdrometer Joss Impact RD-80     Hydrometeorology Testbed - West     2012-10-11     2013-04-17          view
3 GHz Precipitation Profiler Analog     Hydrometeorology Testbed - West     2012-11-02     2013-04-17          view
3 GHz Precipitation Profiler Analog     Hydrometeorology Testbed - West     2013-11-05     2015-06-04          view
Disdrometer Joss Impact RD-80     Hydrometeorology Testbed - West     2013-11-05     2015-06-04          view
Datalogger CR23X     Hydrometeorology Testbed - West     2012-05-23     2021-10-06          view
Disdrometer Joss Impact RD-80     Hydrometeorology Testbed - West     2014-10-08     2015-03-18          view
Disdrometer Joss Impact RD-80     Hydrometeorology Testbed - West     2014-10-08     2015-03-18          view

  OutageID     SiteID     Failure Type     Start Date      End Date      Description     Resolution Description  
896 czc Power Failure 2024-02-04 21:46:00 2024-02-11 23:00:00 Power outage at site Power restored
879 czc Communication - Phone 2023-10-05 16:00:00 2023-12-05 23:22:00 Battery voltage below operating threshold (9.2 V before operations ceased). Also, datalogger data cable chewed by mice and further deteriorated by corrosion. Data cable and datalogger battery replaced.
851 czc Power Failure 2023-03-02 21:45:00 2023-04-12 23:00:00 Suspected power issue at site Power restored
842 czc Communication - Cellular 2023-01-04 19:45:00 2023-01-14 16:45:00 Cellular tower outage Cellular service restored
800 czc Power Failure 2022-01-06 21:45:00 2022-01-12 18:15:00 UPS power output outage; circuit breaker keeps tripping Circuit breaker reset on site
796 czc Hardware - Instrument 2021-12-30 21:43:00 2022-01-06 20:00:00 UPS power output outage; UPS remote interface unreachable Tripped breaker reset
778 czc Hardware - Instrument 2021-05-18 14:00:00 2021-10-06 23:45:00 Radar electronics issue Radar repaired during site visit
675 czc Power Failure 2019-12-07 16:59:00 2019-12-17 17:00:00 Radar PC originally unresponsive; scheduled UPS restart failed Manual on-site restart required of PC and UPS
660 czc Power Failure 2019-10-27 01:59:00 2019-11-01 00:30:00 Can't connect to cellular router; utility power outage Power service returned
654 czc Power Failure 2019-10-17 16:00:00 2019-10-17 22:00:00 Power outage confirmed on the PG&E web site. Power returned.
630 czc Power Failure 2019-02-27 05:00:00 2019-03-13 21:30:00 Can't reach cellular router. Likely power outage. Power restored.
608 czc Hardware - PC 2018-11-05 15:00:00 2018-11-26 22:45:00 computer will not boot computer repaired
607 czc Hardware - Instrument 2018-09-12 17:15:00 2018-10-24 17:00:00 Radar transmitter issue Radar repaired
587 czc Hardware - Instrument 2018-03-30 08:32:00 2018-05-21 20:00:00 Datalogger unreachable. Replaced charging circuit and power line.
555 czc Communication - Phone 2017-10-09 09:00:00 2017-10-11 03:17:00 Router unreachable. Cellular service restored. Wildfire in the vicinity.
515 czc Hardware - Instrument 2017-01-15 15:50:00 2017-02-15 19:00:00 Unable to connect to datalogger from PC using Logger Net. Could be datalogger and/or COM port issue. Tried unsuccessfully rebooting the machine to restore Com port. Issue resolved.
509 czc Hardware - Instrument 2016-11-06 18:14:00 2016-11-07 14:00:00 Datalogger Flux comms issue. DAS machine could not open COM Port. R ebooting the machine fixed the problem. This is the 2nd time this happened so perhaps something up with the DAS at CZC.
426 czc Hardware - Instrument 2014-12-10 02:48:00 2014-12-17 19:00:00 Lost comms between DAS and datalogger. Could be RAD modems going bad as connection was intermittent before complete failure. On last connection, datalogger appears to be health and collecting data. Replaced faulty RAD modems.
399 czc Hardware - PC 2014-08-21 00:00:00 2014-10-08 00:00:00 Cannot connect to DAS machine. Unresponsive. Machine is most likely down or lost power. Update 9/3. Router is intermittent with large outages during outages occurring 18 to 2z. Update 9/12/ Outages are getting worse. May need to replace modem/antennae. Replaced router and UPS backup batteries.
384 czc Hardware - Instrument 2014-05-02 13:00:00 2014-05-10 00:00:00 S-Band getting no return. May have blown a fuse. Powered off for season
366 czc Hardware - Instrument 2014-02-14 08:00:00 2014-04-02 00:00:00 Lost comms with Sonic. Connectivity with Sonic restored.
302 czc Hardware - PC 2013-03-08 00:00:00 2013-03-09 00:00:00 Radar PC failed to reboot. Contact notified to manually restart machine. Contact rebooted machine
281 czc Communication - Cellular 2012-12-14 01:00:00 2012-12-14 22:00:00 Cellular router unresponsive. Could be a power failure or router issue. Charger unplugged. Plugged back in.
273 czc Hardware - Instrument 2012-11-14 23:00:00 2012-12-13 00:00:00 S-band lost sensitivity. Scheduled repairs week of 11/26-30 Transmitter repaired.
226 czc Hardware - Instrument 2012-05-22 17:00:00 2012-05-23 23:00:00 Site undergoing maintenance. Scheduled to be back online 5/24 maintenance completed.
82 czc Power Failure 2011-03-31 19:00:00 2011-04-19 21:30:00 Critical PC failure due to high temperatures in trailer (110 F). Most likely due to an A/C malfunction. Electronics have been shutdown in trailer. Site visit on 4/19/11 determined circuit breaker was tripped. No damage to any equipment/instruments.
63 czc Power Failure 2011-03-21 09:00:00 2011-03-29 19:00:00 Extended power outage in the area. Contact reported power returned on 3/24/11. Since battery backup was exhausted during outage, initial start-up may have tripped the circuit breaker. Power outage restored by PG&E 3/29/11.
38 czc Power Failure 2011-02-16 20:15:00 2011-02-17 01:00:00 Power outage. Backup power system bypassed until new battery charger is installed at the end of February 2011. Power restored.
30 czc Communication - Phone 2011-01-18 20:00:00 2011-01-27 18:00:00 Verizon phone cable damaged by hungry cows. Verizon Technician repaired phone cable. Comms now okay.
24 czc Power Failure 2011-01-08 22:00:00 2011-02-08 02:30:00 Battery charger for the power backup system has failed. Power inverter could not switch to AC mode. No power to equipment. Battery backup system bypassed. New battery charger has been ordered and will be installed at a later date.