Colfax, CA

      Site ID:     cfc
      Latitude:     39.079500 N
      Longitude:     -120.937900 W
      Elevation:     643 meters
      Active:     Y
      Site Table:     Site Table
      Data:     Realtime Display

Instrument Name     Project Name     Install Date     Data Types
Datalogger CR800     Hydrometeorology Testbed - West     2018-01-29          view
Tipping Bucket Heated TE525     Hydrometeorology Testbed - West     2009-10-28          view
Pressure - PTB101B     Hydrometeorology Testbed - West     2009-10-28          view
Temp/RH HMP45C     Hydrometeorology Testbed - West     2009-10-28          view
Wind Speed and Direction 5103     Hydrometeorology Testbed - West     2009-10-28          view
Solar Radiation CM3     Hydrometeorology Testbed - West     2009-10-28          view
Net Radiation REBS Q7.1     Hydrometeorology Testbed - West     2009-10-28          view

Instrument Name     Project Name     Install Date     Removal Date     Data Types
Datalogger CR10X     Hydrometeorology Testbed - West     2009-10-27     2018-01-29          view
915 MHz Wind Profiler Analog     Hydrometeorology Testbed - West     2007-11-13     2015-06-26          view
GpsTrimble NetRS     Hydrometeorology Testbed - West     2009-10-27     2015-06-26          view
Disdrometer Parsivel Optical     Hydrometeorology Testbed - West     2011-12-09     2012-05-08          view

  OutageID     SiteID     Failure Type     Start Date      End Date      Description     Resolution Description  
909 cfc Power Failure 2024-03-25 16:00:00 Power outage due to construction at site
874 cfc Power Failure 2023-08-18 13:45:00 2023-08-28 19:30:00 Unable to connect remotely to UPS Power breaker reset
852 cfc Hardware - Instrument 2023-03-18 15:56:00 2023-04-02 11:00:00 Unable to connect to datalogger on local PC Intermittent connections may indicate low battery voltage, cable connection issue, or cellular service issue
551 cfc Hardware - Instrument 2017-09-22 01:00:00 2017-10-11 01:28:00 Intermittent connectivity issues with datalogger communications interface. Communications to the router are stable. Connectivity stable (from possible site visit).
475 cfc Communication - Cellular 2015-12-13 00:00:00 2015-12-14 00:00:00 Unable to reach cell modem. Router rebooted.
407 cfc Hardware - Instrument 2014-10-03 00:00:00 2014-12-03 00:00:00 Bad battery on datalogger. Update: 10/13/14 - Replaced battery but datalogger continued to experience problems. May need to swap data logger unit. Datalogger replaced.
321 cfc Hardware - Instrument 2013-07-05 17:20:00 2013-07-07 17:20:00 Remote computer can't connect to datalogger. Possible data cable or datalogger issue. Restored
316 cfc Hardware - Instrument 2013-06-28 15:40:00 2013-06-30 00:00:00 Unable to connect to data logger at from DAS machine to datalogger. Datalogger restored functionality on its own.
313 cfc Hardware - Instrument 2013-06-14 20:00:00 2013-09-18 15:00:00 Radar might have faulty transmitter. Radar has been turned off until repaired. Update 7/9/13. Powered off Radar PC due to heat in the trailer. Update 7/16/13. Site visit confirms a blown power supply. Will need to fix on next site visit. Radar repaired.
201 cfc Hardware - Instrument 2012-03-10 11:00:00 2012-04-10 11:00:00 Bad 915MHz UPS causing power loss. By-passed UPS. UPS replaced
193 cfc Communication - Satellite 2012-02-29 05:00:00 2012-02-29 20:00:00 Satellite router unresponsive. Could be a power failure, route rissue, or comms computer issue. System rebooted.
174 cfc Power Failure 2011-12-28 22:00:00 2011-12-29 22:00:00 Satellite router unresponsive. Could be a power failure, router issue or comms computer issue. Breaker tripped due to construction in the area. Power restored.
136 cfc Communication - Satellite 2011-09-04 19:00:00 2011-09-08 19:00:00 Site IP unreachable. Either problem with ISP, satellite equipment, or power issue on site. Satellite equipment fixed at site.
113 cfc Communication - Satellite 2011-07-07 09:00:00 2011-07-13 00:00:00 Satellite router unresponsive. Could be a power failure, router issue or comms computer issue. Sat connection restored on it's own.
44 cfc Power Failure 2011-02-25 02:00:00 2011-02-25 16:00:00 Power outage in the area. Power restored.
40 cfc Power Failure 2011-02-17 22:00:00 2011-02-22 20:00:00 30 amp circuit breaker was tripped causing power loss. Circuit breaker turned back on to restore power.