OutageID |
SiteID |
Failure Type |
Start Date |
End Date |
Description |
Resolution Description |
521 |
cco |
Hardware - Instrument |
2017-03-27 02:00:00 |
2017-07-27 19:00:00 |
Antenna component failure on the 138-degree oblique beam. |
Radar repaired on-site by PSD engineer. |
478 |
cco |
Hardware - Instrument |
2015-12-21 00:00:00 |
2016-03-18 00:00:00 |
Can't connect to GpsTrimble via Serial COM port on radar PC. |
GpsTrimble R7 replaced with a NetRS. |
474 |
cco |
Hardware - Instrument |
2015-11-00 00:00:00 |
2016-01-22 00:00:00 |
RASS issues at the site. |
RASS fixed. |
454 |
cco |
Hardware - Instrument |
2015-06-08 00:00:00 |
2015-10-20 22:00:00 |
Faulty A/C. Powered down to prevent damage. |
AC replaced. |
365 |
cco |
Hardware - Instrument |
2014-02-14 06:00:00 |
2014-02-28 00:00:00 |
Trimble not tracking satellites. |
Trimble replaced. |
349 |
cco |
Communication - Cellular |
2013-10-02 16:00:00 |
2013-10-10 16:00:00 |
Lost comms to cellular router. |
comms restored. |
342 |
cco |
Communication - Cellular |
2013-09-02 00:00:00 |
2013-09-24 21:00:00 |
Cellular router unreachable. Power outage likely.
Ground squirrel chewed antennae cable. Replacement sent. |
New antennae replaced. |
307 |
cco |
Power Failure |
2013-04-30 23:00:00 |
2013-05-03 19:00:00 |
Lost comms to cellular router. |
Circuit was accidentally tripped by nearby residents. |
244 |
cco |
Hardware - Instrument |
2012-07-02 23:00:00 |
2012-10-11 23:00:00 |
Faulty A/C at site caused thermostat to power down site.
Site will be offline until A/C is replaced. Estimated 1st week of August. Update 8/7/12 - Computer electronics damaged from heat. Site will run as stand alone Surface Met station and data will be collected but not in real-time. |
A/C replaced and computer electronics replaced. |
231 |
cco |
Communication - Cellular |
2012-06-02 00:00:00 |
2012-06-02 03:00:00 |
Cannot reach cellular modem. Could be power problem, hardware/pc problem, or router problem. |
Connection restored. |
212 |
cco |
Communication - Cellular |
2012-04-17 07:00:00 |
2012-04-19 00:00:00 |
SCP transfer protocol timing out due to poor connection. |
connection speeds improved. SCP transferring at acceptable rate. |
138 |
cco |
Hardware - Instrument |
2011-08-12 15:00:00 |
2011-09-13 23:00:00 |
GPS Trimble unreachable. Either problem with power or equipment. Site visit scheduled for 9/13/11. |
GPS trimble antenna cable was chewed through by animals. Fixed cable. |
87 |
cco |
Communication - Phone |
2011-04-24 19:00:00 |
2011-04-25 00:00:00 |
Modem unresponsive. Could be a power failure, modem, phone line, or PC issue. |
Phone line connection restored w/o intervention. |
102 |
cco |
Hardware - Instrument |
2010-11-21 00:00:00 |
2010-11-30 17:10:00 |
During site visit on 11/30/10 the tipping bucket was found to be not functioning. The last time the TB recorded precipitation was on 11/21/10. |
A short was found in the cable and was repaired. |